M:n redundancy switch
Hide thumbs Also See for Radyne RCS20:
Table of Contents

Advertisement

RCS20 M:N Redundancy Switch
Remote Operations
<1>
Switch Major Alarms
<1>
Switch Minor Alarms 1
<1>
Switch Minor Alarms 2
Bit 0 = RAM/ROM fault
Bit 1 = No Backup for Faulted Prime
Bit 2 = Error During Backup
Bit 3 = Backup 1 Mod Error
Bit 4 = Backup 1 Demod Error
Bit 5 = Backup 2 Mod Error
Bit 6 = Backup 2 Demod Error
Bit 7 = Spare
(0 = no alarm, 1 = alarm)
Bit 0 = Power Supply #1 Present
Bit 1 = Power Supply #1 Voltage
Bit 2 = Power Supply #2 Present
Bit 3 = Power Supply #2 Voltage
Bit 4 = Communications Error
Bit 5 = Faulted Prime Modem
Bit 6 = Faulted Backup Modem
Bit 7 = Modem Configuration Change
(0 = no alarm, 1 = alarm)
Bit 0 = CDM Error
Bit 1 = Reserved (RCS10 only)
Bit 2 = Reserved (RCS10 only)
Bit 3 = Reserved (RCS10 only)
Bit 4 = Backup 1 Test Fault
Bit 5 = Backup 2 Test Fault
Bit 6 = Reserved (RCS10 only)
Bit 7 = Spare
(0 = no alarm, 1 = alarm)
A–23