Comtech EF Data Radyne RCS20 Installation And Operation Manual page 170

M:n redundancy switch
Hide thumbs Also See for Radyne RCS20:
Table of Contents

Advertisement

RCS20 M:N Redundancy Switch
Remote Operations
<1>
Backup 2 (Channel 9)
Backup Mode
<1>
Backup 2 (Channel 9)
Force Manual
Modulator Backup
<1>
Backup 2 (Channel 9)
Force Manual
Demodulator Backup
<4>
Reserved
<4>
Reserved
<1>
Reserved
<1>
Reserved
<1>
Reserved
<1>
Learned Modem
<1>
Test Modem
This byte should be forced to 10 if no tests are desired, failure to do so may result in
momentary loss of link on selected modem(s).
<1>
Additional Bytes per
Channel
<1>
*Channel 0 Alarm 2
Mask
<1>
*Channel 0 Alarm 3
Mask
0 = Manual, 1 = Automatic non-Revertive, 2 = Automatic Revertive
Channel number for manual backup (1 to 8) (ignored if in automatic
mode or if channel 9 is configured as prime)
Channel number for manual backup (1 to 8) (ignored if in automatic
mode or if channel 9 is configured as prime)
(Reserved for RCS10, set to zero)
(Reserved for RCS10, set to zero)
(Reserved for RCS10, set to zero)
(Reserved for RCS10, set to zero)
(Reserved for RCS10, set to zero)
0 = Modem 0, 1 = Modem 1, 2 = Modem 2, 3 = Modem 3, 4 = Modem
4, 5 = Modem 5, 6 = Modem 6, 7 = Modem 7, 8 = Modem 8, 9 =
Modem 9, 10 = All Modems
0 = Modem 1, 1 = Modem 2, 2 = Modem 3, 3 = Modem 4, 4 = Modem
5, 5 = Modem 6, 6 = Modem 7, 7 = Modem 8, 8 = Modem 9, 9 = All
Modems, , 10 = None
6 bytes as of release 4.0
Bit 0 = Mod learned
Bit 1 = Demod learned
Bit 2 = Mod configuration changed
Bit 3 = Demod configuration changed
Bits 4 through 7 = Spares
(0 =Mask, 1 = Allow)
Bits 0 and 1 = Mod Backup 1 Test Status Mask
Bits 2 and 3 = Demod Backup 1 Test Status Mask
Bits 4 and 5 = Mod Backup 2 Test Status Mask
Bits 6 and 7 = Demod Backup 2 Test Status Mask
(0 = Mask, 1 = Allow)
A–30
Revision 15
MN-RCS20 and CD-RCS20

Advertisement

Table of Contents
loading