Power Source - Troubleshooting - Fronius TransTig 2200 Comfort Operating Instructions Manual

Table of Contents

Advertisement

Power source -
Power source does not function
troubleshooting
Mains switch is on, but indicators are not lit up
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
No welding current
Mains switch is ON, overtemperature indicator is lit up
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
No welding current
Mains switch is on, indicators are lit up
Cause:
Remedy:
Cause:
Remedy:
Nothing happens when the torch trigger is pressed
Mains switch is on, indicators are lit up
Cause:
Remedy:
Cause:
Remedy:
180
There is a break in the mains lead; the mains plug is not plugged in
Check the mains lead, ensure that the mains plug is plugged in
Mains socket or mains plug faulty
Replace faulty parts
Mains fuse protection
Change the mains fuse protection
Overload
Check duty cycle
Thermostatic safety cut-out has tripped
Wait until the power source automatically comes back on after the end of the
cooling phase
The fan in the power source is faulty
Contact After-Sales Service
Grounding (earthing) connection is incorrect
Check the grounding (earthing) connection and terminal for correct polarity
There is a break in the current cable in the welding torch
Replace welding torch
The control plug is not plugged in
Plug in the control plug
Welding torch or welding torch control line is faulty
Replace welding torch