Fronius TransTig 2200 Comfort Operating Instructions Manual page 149

Table of Contents

Advertisement

Final current time
Unit
s
Setting range
OFF / 0.01 - 9.9
The final current time t-E specifies the duration of the final current phase I
IMPORTANT!The final current time only applies in 2-step mode. In 4-step mode, the du-
ration of the final current phase I
modes").
Current crrctn.
main current I1 correction range for job retrieval
Unit
%
Setting range
OFF / 1 - 100
IMPORTANT!The I1 correction range only applies to job retrieval.
In the jobs, all the settings are permanently saved, i.e. cannot be changed. However, the
parameter "current crrctn" permits subsequent correction of the main current I1.
Example
The set-up parameter "current crrctn" has been set to 30%:
-
The welding current I1 can then be decreased or increased by up to 30%.
IMPORTANT! Every subsequent correction of the main current I1 is reset (i.e. cancelled)
when the power source is switched off.
Operating mode
Unit
-
Setting range
2t / 4t
2-step
2-step mode
4t
4-step mode
Wirefeed spd
Wire feed speed 1 (when cold wire-feed unit option is available)
Unit
m/min
Setting range
OFF / 0.1 - max.
Wirefeed spd2
Wire feed speed 2
Unit
% (of the wire feed speed)
Setting range
0 - 100
If a value is set for both 'wire feed speed 2' and 'pulse frequency', then the wire feed speed
alternates between the following values in sync with the pulse frequency of the welding
current:
-
Wire feed speed 1
-
Wire feed speed 2
Start-delay
Delay in the start of wirefeeding from beginning of the main current phase
Unit
s
Setting range
OFF / 0.1 - 9.9
is controlled with the torch trigger (see: "TIG operating
E
ipm
OFF / 3.9 - max.
.
E
149

Advertisement

Table of Contents
loading

Table of Contents