Technical Data; Special Voltages; Magicwave2200 Comfort - Fronius TransTig 2200 Comfort Operating Instructions Manual

Table of Contents

Advertisement

Technical data

Special voltages

MagicWave
2200 Comfort
Mains voltage
Mains voltage tolerance
Mains frequency
Mains fuse protection (slow-blow)
Mains connection
Primary continuous power (100% d.c.
Cos phi
Welding current range
Welding current at
Open circuit voltage
Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
Type of cooling
Insulation class
EMC emission class
(in accordance with EN/IEC 60974-10)
Dimensions L x W x H (with handle)
Weight (without handle)
Weight (with handle)
Mark of conformity
NOTE! An inadequately dimensioned electrical installation can cause serious
damage. The mains cable and its fuse must be dimensioned accordingly.
The technical data shown on the rating plate applies.
1)
TIG
Electrode
10 min/25 °C (77 °F) 40% d.c.
10 min/25 °C (77 °F) 60% d.c.
10 min/25 °C (77 °F) 100% d.c.
10 min/40 °C (104 °F) 35% d.c.
10 min/40 °C (104 °F) 60% d.c.
10 min/40 °C (104 °F) 100% d.c.
TIG
Electrode
)
p
MW 2200 Comfort
230 V
-20 % / +15 %
50/60 Hz
16 A
No restrictions
2)
)
3.7 kVA
0,99
3 - 220 A
10 - 180 A
2)
220 A
2)
180 A
2)
150 A
2)
220 A
2)
170 A
2)
150 A
88 V
10.1 - 18.8 V
20.4 - 27.2 V
9.5 kV
IP 23
AF
B
A
485 / 180 / 390 mm
19.1 / 7.1 / 15.4 in.
17.4 kg
38.3 lb.
17.8 kg
39.2 lb.
S, CE
187

Advertisement

Table of Contents
loading

Table of Contents