Fronius TransTig 2200 Comfort Operating Instructions Manual page 125

Table of Contents

Advertisement

Remedy:
Engage the drive units of both wire-feed unit motors, arrange the hosepack
in as straight a line as possible; check the inner liner for kinks or soiling;
check the contact pressure on the 2-roller or 4-roller drive of the push-pull
unit. Repeat the push-pull calibration. If the error message re-appears: Con-
tact After-Sales Service.
Remedy:
Engage the drive units of both wire-feed unit motors, arrange the hosepack
in as straight a line as possible; check the inner liner for kinks or soiling;
check the contact pressure on the 2-roller or 4-roller drive of the push-pull
unit. Repeat the push-pull calibration. If the error message re-appears: Con-
tact After-Sales Service.
Cause:
At maximum wire feed speed, the
motor current of the wire-feed unit
motor is outside the permitted
range. Possible reasons are dis-
engaged wire-feed unit motors or
wire feed problems.
Cause:
At maximum wire feed speed, the
motor current of the push-pull unit
is outside the permitted range.
Possible reasons are disengaged
wire-feed unit motors or wire feed
problems.
Cause:
Push-pull calibration was inter-
rupted: Quick-stop was activated
by pressing the torch trigger.
Remedy:
Repeat push-pull calibration