Fronius TransTig 2200 Comfort Operating Instructions Manual page 152

Table of Contents

Advertisement

Setting example: I1 = 250 A, arc-force dynamic = 50
The characteristics (4), (5) and (6) shown here apply when using a rod electrode whose
characteristic corresponds - at a given arc length - to the load line (1).
Depending on what welding current (I) has been set, the point of intersection (operating
point) of characteristics (4), (5) and (6) will be displaced along the load line (1). The oper-
ating point provides information on the actual welding voltage and the actual welding cur-
rent.
Where the welding current (I
the characteristics (4), (5) and (6) depending on the welding voltage at that moment in time.
The welding voltage U is dependent upon the length of the arc.
If the arc length changes (e.g. in accordance with the load line (2)) the resulting operating
point will be the point where the corresponding characteristic (4), (5) or (6) intersects with
the load line (2).
Applies to characteristics (5) and (6): Depending upon the welding voltage (arc length), the
welding current (I) will also become either smaller or larger, even though the value set for
I
1
Polarity
Unit
Setting range
152
(8)
(a)
U (V)
(6)
60
50
(a)
(b)
40
(5)
30
20
(4)
10
1
0
0
200
I
- 50 %
1
remains the same.
-
AC (only MagicWave) / DC- / DC+
(1)
(2)
(3)
(2)
(4)
(1)
(c)
(3)
(5)
(c)
(6)
(7)
I (A)
3
0
0
4
0
0
(7)
I
+ Dynamik
1
(8)
(a)
(b)
(c)
) is permanently set, the operating point may migrate along
1
Load line for rod electrode
Load line for rod electrode where arc length is in-
creased
Load line for rod electrode where arc length is re-
duced
Characteristic where "CON" parameter is select-
ed (constant welding current)
Characteristic where "0.1 - 20" parameter is se-
lected (drooping characteristic with adjustable
slope)
Characteristic where "P" parameter is selected
(constant welding power)
Example of pre-set arc-force dynamic where
characteristic (5) or (6) is selected
Possible change in the current where character-
istic (5) or (6) is selected, as a function of the
welding voltage (arc length)
Operating point where arc length is long
Operating point when welding current IH is set
Operating point where arc length is short