Main current: starting current < main current ("SoftStart")
Main current: starting current > main current ("HotStart")
Unit
Setting range
Factory setting
To obtain optimum welding results, it will sometimes be necessary to adjust the arc-force
dynamic.
Unit
Setting range
Factory setting
0
100
Functional principle:
at the instant of droplet transfer or when a short circuit occurs, there is a momentary rise
in amperage. In order to obtain a stable arc, the welding current is temporarily increased.
If the rod electrode threatens to sink into the weld pool, this measure prevents the weld
pool solidifying, as well as preventing more prolonged short circuiting of the arc. This
largely prevents the rod electrode from sticking.
76
A
MW 2500 Comfort 3 - 250
MW 3000 Comfort 3 - 300
-
% (of main current)
0 - 100
20
soft, low-spatter arc
harder, more stable arc
Main current: starting current = main current
TT 2500 Comfort 3 - 250
TT 3000 Comfort 3 - 300