Polarity
Unit
Setting range
AC frequency
only with MagicWave for the TIG AC welding process
Unit
Setting range
Syn
IMPORTANT!If using the "Syn" setting, remember to check the "Phase sync." parameter
in AC setup 2nd.
Low frequency
High frequency
AC-current offset
only with MagicWave for the TIG AC welding process
Unit
Setting range
+70
-70
Balance
only on MagicWave for TIG AC welding process
Unit
Setting range
-5:
+5:
Spot welding time
Unit
Setting range
If a value has been set for the spot welding time, "2-step mode" will work in the same way
as spot welding mode.
Starting current time
Unit
Setting range
The starting current time t-S specifies the duration of the starting-current phase I
IMPORTANT!The starting current time only applies in 2-step mode. In 4-step mode, the
duration of the starting-current phase I
148
-
AC (only MagicWave) / DC- / DC+
Hz
Syn / 40 - 250
for mains synchronisation of two power sources for simultaneous
AC welding.
soft, distant arc with shallow heat input
focused arc with deep heat input
%
-70 to +70
highest fusing power, lowest cleaning action
narrow arc, deep heat input, faster welding speed
-
-5 - +5
distant arc with shallow heat input
highest cleaning action, lowest fusing power
s
OFF / 0.05 - 25.0
s
OFF / 0.01 - 9.9
is controlled using the torch trigger
s
.
s