Figure 4-18: Applications Menu - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual
4.2.8 ADVANCE MEAS. Menu [iX Series only]
This entry in the MENU 2 screen displays the HARMONICS/TRACE ANALYSIS screen which is
covered in section 4. This field can be used in lieu of the MEAS key to directly bring up the
advanced measurements screens.
4.2.9 APPLICATIONS Menu
The APPLICATIONS menu provides access to the optional application specific pre-programmed
test sequences. Since these test sequences are optional, this menu may have no choices if none
of the options are installed. The following entries may be found in the APPLICATIONS menu:
Entry
MIL-STD 704
OMNI OPTION
RTCA/DO-160
IEC-1000-4-11
IEC-1000-4-13
64

Figure 4-18: APPLICATIONS menu

Description
Test sequence for MIL standard 704 AC and DC tests.
This entry selects the OMNI control menu. The OMNI option
provides a lumped reference impedance for use in IEC 1000-3-3
Flicker test applications. The iX Series also provides
programmable impedance, so, in most cases, the OMNI option
is not required. For the i Series, the OMNI impedance is
available as an option. If the OMNI option is installed, this
screen allows the impedance to be ENGAGED or BYPASSED.
Test sequence for RTCA DO160 commercial aviation AC and
DC tests.
Test sequences for IEC 1000-4-11 Voltage Dips and Variations
test standard.
Test sequence for IEC 1000-4-13 Harmonics and
Interharmonics test standard.
i Series / iX Series