2.6 Special Features, Options and Accessories

Programmable
Impedance.
Parallel Operation:
Three Phase Output:
Rack Mount/Handles
Version:
Controller:
Output Relay:
Output On/Off:
Three-Phase Output
9003iX/15003Ix
15003iX – LKM/-LKS
- 704
- 160
- 411
- 413
-ABD
- LNS
-MODE-iX
- RMS
-OMNI-1-18i
-OMNI-1-37i
-OMNI-3-18i
i Series / iX Series
Output impedance programming available on models 3001iX,
5001iX, 9003iX and 15003iX only.
Up to three units can be paralleled in a single-phase configuration
(with one master controller and one or two slave units). (10001iX
and 15001iX).
Three units (all with single-phase controllers) can be connected in
a three-phase configuration using CLOCK and LOCK connections.
Requires –LKM option in master and –LKS option in auxiliary
units. Recommended is use of 9003iX, 15003iX or 30003iX three
phase system however.
Available rack mounting kit with slides and handles. Handles also
available as a separate option.
Programmable controller front panel assembly.
Standard output relay feature to isolate AC source from the load.
The output relay can be used to quickly disconnect the load. A
green status indicator displays the status of the output relay.
Three power sources with one controller in the Phase A power
source. The one controller controls all three outputs.
Three power sources each with a controller for 3-phase output
Mil Std 704D & E test firmware.
Mil Std 704A, B, C, & F test software.
Note: Requires use of CIGui32 Windows application software provided
on CD ROM CIC496.
RTCA/DO-160C test firmware
IEC 1000-4-11 test firmware
IEC 1000-4-13 test firmware
Airbus ABD0100.1.8 Test firmware.
Note: Requires use ofCIGui32 Windows application software provided on
CD ROM CIC496.
Line sync option to synchronize output frequency to input mains
line frequency
Available for 9003iX and 15003iX configurations only. Switches
output configurations between single-phase and three-phase
mode of operation. Note that programmable impedance function
on systems with –MODE-iX option is only available when in 3
phase mode.
Rack mount slides
Single phase lumped reference impedance network of IEC1000-3-
3 Flicker test
Single phase lumped reference impedance network of IEC1000-3-
3 Flicker test – High current.
Three phase lumped reference impedance network of IEC1000-3-
13