Figure 9-68: Abd Option Eut Measurement Data Screen - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual
9.9.9 ABD EUT Performance Measurements
The EUT Performance Measurements tab in the ABD tests window provides measurement data
taken by the power source‟s data acquisition system. It also analyzes the data where applicable
and compares against performance limits set by the ABD test standard. This tab contains four
sub-tabs that each present different aspects of the EUT measurement data. Additional user
controls for measurement updates and graph scaling are provided right next to the four sub tabs.
The following sub tabs are available for selection.
Sub-Tab
Parameters
300

Figure 9-68: ABD Option EUT Measurement Data Screen.

Description
This tab displays the parametric measurement data in tabular form. This includes
voltage, current, power, power factor, distortion etc. For three-phase EUT‟s data is
shown for all three phases. For single phase EUT, data is shown for phase A only
as long as the power source is in single-phase mode.
The top half of the Parameters tab displays all parametric measurement data. The
following data is available:
Volt RMS (V)
Displays source voltage per phase in Volt RMS or DC
depending on power source mode of operation.
Curr RMS (A)
Displays EUT current per phase in amps RMS or DC
depending on power source mode of operation.
App. Power (VA)
Displays the apparent power for each phase as well as the
total power for all three phases.