9.7 LNS Option and XLS Option

The Line Sync option and the External Line Sync option both provide the same function, namely
synchronizing the iX output to the input line. The LNS option is internal to the iX power source
and will sync the output to the iX input line only.
The XLS option however, is external to the power source, it can be added to the source as
needed and it will sync to any line voltage whether it is connected to the iX source or not.
9.7.1 Specifications
The -LNS and -XLS options meet the following specifications. The specifications shown here are
for these line sync options only. All other power source specifications for i Series and iX Series
power systems are covered in their respective data sheets.
Internal Line Sync (-LNS)
AC Line Voltage input
Frequency
Phase offset
Phase error
External Line Sync (-XLS)
AC Line Voltage input
Frequency
Phase offset
Phase error
Input connectors
Interface to Power Source
Note: During external sync mode operation, some features such as clock and lock mode,
external sync and frequency transients are disabled.
i Series / iX Series
Taken from AC input
Internally in power source
45 – 66
0.0° - 360.0°
± 1.0°
80 – 250
Low range
250 – 500
High range
45 – 66
0.0° - 360.0°
± 1.0°
Banana Jacks
Screw Terminals
36 Pin System Interface
Hz
V RMS
V RMS
Hz
233