Table 9-18: -160 Option Test Coverage, 230Vac And 14Vdc - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual
No.
230V Tests
Description
Voltage and
16.5.1.1
Frequency
16.5.1.2
Voltage Modulation
Frequency
16.5.1.3
Modulation
Momentary Power
16.5.1.4
Interruptions
Normal Surge
16.5.1.5.1
Voltage
Normal Frequency
16.5.1.5.2
Transients
Normal Frequency
16.5.1.6
Variations
Voltage DC
16.5.1.7
Content
16.5.1.8
Voltage Distortion
Abnormal Voltage
16.5.2.1
and Frequency
Momentary Under
16.5.2.2
Voltage Operation
Abnormal Surge
16.5.2.3.1
Voltage
Abnormal
16.5.2.3.2
Frequency
Transient
Note that the iX Series does not support 800 Hz testing at more than 150Vrms. Consequently, all
230V nominal tests for A(NF) and A(WF) categories are not supported. Some A(CF) tests
requiring more than 300V output are also unavailable due to hardware limitations of the iX Series
power source.
152
Table
Table
Table
A(CF)
A(NF)
A(WF)
X
X
X
X
X
X
X
X
X
X
X
X
X
N/A
X
X
X
X
P
X
X
X
X
X
X
X
X
X
X
X

Table 9-18: -160 Option Test Coverage, 230VAC and 14VDC

No.
14 VDC Tests
Description
16.6.1.1
Voltage
16.6.1.2
Ripple Voltage
Momentary Power
16.6.1.3
Interruptions
Normal Surge
16.6.1.4
Voltage
Engine Starting
16.6.1.5
Under Voltage
16.6.2.1
Abnormal Voltage
Low Voltage
16.6.2.2
Conditions
Momentary Under
16.6.2.3
Voltage Operation
Abnormal Voltage
16.6.2.4
Surge
Table
Table
Table
ADC
BDC
ZDC
P
P
P
N/A
N/A
N/A
i Series / iX Series

Hide quick links:

Advertisement

Table of Contents
loading