Figure 9-32: Iec 61000-4-13 Test Flowchart Class 1 And 2 - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual
Start - Class 1/2
Determine appropriate test
configuration
Perform 8.2.1 Test
"Harmonic combination"
Flatcurve and Overswing
Any functional
anomalies?
Yes
Test Completed
FAIL
Record Results
i Series / iX Series
Yes
Class 2
required?
No
Perform 8.2.2 Test
"Frequency Sweep"
Any functional
anomalies?
Perform 8.2.3 Test
"Individual Harmonics/
Interharmonics"
Yes
Any functional
anomalies?

Figure 9-32: IEC 61000-4-13 Test Flowchart Class 1 and 2

Yes
Meister
curve required?
No
No
Yes
Yes
No
Yes
Perform 8.2.4 Test
"Meister Curve"
Any functional
anomalies?
No
Test Completed
PASS
Record Results
195

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents