Table 9-16: Abnormal Voltage Surge - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual
VOLT SURGE
This test will produce voltage surge defined by Table 9-16. This test will be repeated three times
with ten seconds intervals. The voltage values are halved for 14.0V category B equipment.
Category
A
B
Z
9.1.1.6.3 Emergency Test
The Emergency test is selected from the DO-160 DC Main Menu. This test will set the output
voltage to 18V for 28V equipment and to 9V for 14V equipment. The test will last for 30 minutes.
The
key (backspace) will terminate the test at any time.
i Series / iX Series
Surge 1
Volt
Dwell(msec)
46.3
100
60
100
80
100

Table 9-16: Abnormal Voltage Surge

Surge 2
Volt
Dwell(msec)
37.8
1000
40
1000
48
1000
149

Hide quick links: