Table 9-17: -160 Option Test Coverage, 115Vac And 28Vdc - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual
This section of the manual covers operation of the –160 option using the CIGui32 program.
Version 1.26 or higher of the CIGui32 program is required. The CIGui32 program is supplied with
all iX systems free of charge on CD ROM CIC496. It can also be downloaded from the California
Instruments web site (www.calinst.com).
The information provided in this user manual is aimed at guiding the operator in the use of the
160 option through the use of the CIGui32 program. Much of the same information can be found
in the on-line help system of the CIGUI32.
This manual is not intended to elaborate on the intent or purpose of the immunity tests and the
expected behavior of the EUT as described in the RTCA/DO-160 documents. It is assumed that
the end-user is familiar with the content of the RTCA/DO-160 test standard.
9.1.2.2 Test Coverage
The comprehensiveness of the tests that can be performed with the –160 option is determined
primarily by the capabilities of the power source used. Tests that are outside the hardware
capabilities of the power source used will not be enabled and cannot be selected. For these
tests, additional equipment may be required as indicated. The extent of coverage of the –160
option as implemented on the iX Series platform is shown in the table below. Tests marked with
an „x‟ generally require additional hardware to be used. Tests marked „N/A‟ are not applicable to
the corresponding table. Tests marked with a „ ‟ are covered by the –160 option. Tests marked
with a „P‟ are limited in scope and may require additional equipment to perform completely.
No.
115V Tests
Description
Voltage and
16.5.1.1
Frequency
16.5.1.2
Voltage Modulation
Frequency
16.5.1.3
Modulation
Momentary Power
16.5.1.4
Interruptions
Normal Surge
16.5.1.5.1
Voltage
Normal Frequency
16.5.1.5.2
Transients
Normal Frequency
16.5.1.6
Variations
Voltage DC
16.5.1.7
Content
16.5.1.8
Voltage Distortion
Abnormal Voltage
16.5.2.1
and Frequency
Momentary Under
16.5.2.2
Voltage Operation
Abnormal Surge
16.5.2.3.1
Voltage
Abnormal
16.5.2.3.2
Frequency
Transient
i Series / iX Series
Table
Table
Table
A(CF)
A(NF)
A(WF)
N/A
N/A
N/A
P
P
P
N/A
N/A

Table 9-17: -160 Option Test Coverage, 115VAC and 28VDC

No.
28 VDC Tests
Description
16.6.1.1
Voltage
16.6.1.2
Ripple Voltage
Momentary Power
16.6.1.3
Interruptions
Normal Surge
16.6.1.4
Voltage
Engine Starting
16.6.1.5
Under Voltage
16.6.2.1
Abnormal Voltage
Low Voltage
16.6.2.2
Conditions
Momentary Under
16.6.2.3
Voltage Operation
Abnormal Voltage
16.6.2.4
Surge
Table
Table
Table
ADC
BDC
ZDC
P
P
P
N/A
N/A
N/A
151