Specifications; Electrical - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual

2. Specifications

All specifications are for a single i or iX series chassis and 25
resistive load unless noted otherwise.

2.1 Electrical

2.1.1 Input
Parameter
Line Voltage:
Line VA:
Line Current:
Line Frequency:
Efficiency:
Power Factor:
Inrush Current:
Hold-Up Time:
Isolation Voltage:
2
3001i & Ix
208-240 10% VAC, single phase
5000VA
25 A RMS max. (Per Box)
80% (typical) depending on line and load
0.7 (typical)
100 A
for 100 s
pk
2200 VAC input to output
1350 VAC input to chassis
5 C sine wave output with a
5001i & iX
208-240 V
10%, (Standard)
LL
400-440 V
10%, (-400)
LL
400-480 V
10%, (-400)
LL
3 phase, 3 wire + ground
8000VA
23 A RMS max. at 208-240 VAC
12 A RMS max. at 400-440 VAC
and 400-480 VAC (Per Box)
50-60 Hz 10%
0.9 (typical)
100 A
for 100 s at 208-240V
pk
50 A
for 100 s at 400-440 VAC
pk
and 400-480 VAC
15 ms
i Series / iX Series