Figure 9-4: Voltage Modulation; Figure 9-5: Frequency Modulation; Table 9-23: -Abd Option Test Coverage - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual
This manual is not intended to elaborate on the intent or purpose of the immunity tests and the
expected behavior of the EUT as described in the ABD0100.1.8 documents. It is assumed that
the end-user is familiar with the content of the ABD test standard.
9.9.2 Test Coverage
The comprehensiveness of the test that can be performed with the –ABD options is determined
primarily by the capabilities of the power source used. Tests that are outside the hardware
capabilities of the power source used will not be enabled and cannot be selected. For these
tests, additional equipment may be required as indicated. The extent of coverage of the –ABD
option as implemented on the i/iX Series platform is shown in the table below. Tests marked with
an „x‟ generally require additional hardware to be used.
No.
Description
1
Steady State
Voltage
2
Abnormal Steady
State Voltage
3
Voltage Surge -
Normal
4
Voltage Surge -
Abnormal
5
Voltage Spikes
6
Switching
Transients –
Appendix 1
7
Voltage
Modulation
8
Normal
Frequency
Variations
9
Frequency
Modulation
10
Distorted Voltage
290
Table
Table
Table
No.
A
B
C
X
X
X

Table 9-23: -ABD Option Test Coverage

Description
Table
D
1
Steady State
Voltage
2
Abnormal Steady
State Voltage
3
Voltage Surge -
Normal
4
Voltage Surge -
Abnormal
5
Voltage Spikes
X
6
Switching
Transients –
Appendix 1
7
Square Wave
8
Ripple Voltage
X
No.
Description
Table
1
Steady State
Voltage
2
Voltage Surge -
Normal
3
Voltage Surge -
Abnormal
4
Voltage Spikes
5
Switching
Transients –
Appendix 1
6
Ripple Voltage
7
Starting Current
i Series / iX Series
E
X
X

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents