9.10 WHM Option

9.10.1 General
This section describes the WHM option for the i / iX Series Power Source.
9.10.2 Specification
All specifications are the same as the standard i / iX Power Source specifications in addition to
the following specifications:
Watt-hour
0-6.000KW
>6.000KW
9.10.3 Local Operation
From the Menu screen 2, select the APPLICATIONS SETUP 2 screen. The screen will appear
as shown in Figure 9-70. Use the up and down key to position the cursor to the WH METER
field. Press the Enter Key.
The WATT-HOURS METER screen shown in Figure 9-71 has the following fields:
START: This field will activate the watt-hour measurements. Moving the shuttle clockwise when
the field is highlighted will activate the watt hour function and the field will change to STOP as
shown in Figure 9-72.
1. ETIME: This field will accumulate the time in hours, minutes and seconds.
2. WATT HR: This field will accumulate the watt-hour in KWH.
3. POWER: This field will report the instantaneous power in KW.
4. PK CURR: This field will report the peak current and will hold the maximum reading.
i Series / iX Series
0.01KWH + 0.1% <100Hz
0.02KWH +0.1% 100-500Hz
Times three of the above specification

Figure 9-70: Application Screen

Figure 9-71 Watt-Hour Meter Screen