Figure 9-63: 704 Option Test Selection Screen - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual
9.8.2.6 CIGui32 -704 Control Window
To access the –704 option, select the MIL-STD-704 Tables A-F from the Applications menu of
the CIGui32 main screen or click on the 704 button in the toolbar. The 704 Tables control window
will open selecting the power group that most closely matches the steady state values set. It
may still be necessary to select the desired power group first however. Also verify that the
selected power group in the 704 screen is the correct one for the EUT being tested.
The 704 tests can be operated from the 704 test screen. This screen contains three main tabs
located along the top edge of the window. The following tabs are available. Click on the tab name
for additional help on how to use each tab.
Tab
Test Selection
Test Control
EUT Performance
i Series / iX Series

Figure 9-63: 704 Option Test Selection Screen.

Description
This tab allows the operator to select the library of test files to use (Select
Airframe) and the relevant Power group. It also displays the AC power source
settings that are in effect on the right hand side. Available power group
selections are SAC, TAC, SVF, TVF, and SXF for AC products and LDC and
HDC for DC products. The table shown at the bottom of this tab shows the
available test sections that can be selected. This table matches the test
tables of the MIL-STD-704 test standard.
This tab provides information on the test sequence that is presently selected
and also contains the execution controls. It shows the progress of any test that
is executing.
This tab may be used to display EUT performance data as measured by the
257