Figure 9-7: Power Interrupt For Group 2 And 3; Table 9-4: Normal Voltagesurge Sequence - Ametek i Series User Manual

Table of Contents

Advertisement

User Manual
F1
T2
Test no.
T1 (ms)
F1 (Hz)
F2 (Hz)
Fmax = 650 Hz for Group 2
Fmax = 800 Hz for Group 3
T2 = 20 msec
T3 = 5 msec
VOLTAGE SURGE
This test requires 160 volts output. If the power source is set at the low voltage range, the high
voltage range will be selected before the test starts. At the end of the test, the power source will
be switched back to the low range automatically
Seq. No.
1
2
3
4
5
The output voltage will follow the sequence in Table 9-4. The above sequence will repeat itself
three times. Each repeat will start from sequence two. US and Group 1 will run at 400 Hz.
Group 2 and Group 3 will run at 360 Hz and 650 Hz for Group 2 and 800 Hz for Group 3. The
frequency will return to the nominal setting when the test is completed. The
will terminate the test at any time.
i Series / iX Series
T1
0 Volt
T3
21(I)
22(II)
50
50
360
Fmax
Fmax
360

Figure 9-7: Power Interrupt for Group 2 and 3

RTCA
Group 1
115
115
160
160
115
115
60
70
115
115

Table 9-4: Normal VoltageSurge Sequence

F2
23(III)
24(IV)
100
100
360
Fmax
Fmax
360
Voltage
Group 2
115
160
115
70
115
25(V)
26(VI)
200
200
360
Fmax
Fmax
360
Time
Group 3
ALL
115
5 Minute
170
30msec
115
5 Sec.
70
30msec
115
5 Sec.