2.
Specifications
All specifications at 25 5 C unless noted otherwise.
2.1.
Electrical
2.1.1.
Input
Line Voltage:
Line Current:
Line Frequency:
Efficiency:
Power Factor:
Inrush Current:
Hold-Up Time:
Isolation Voltage:
2.1.2.
Output
Voltage Range:
Voltage Resolution:
Voltage Accuracy:
Line & Load Regulation:
Voltage Distortion:
Total Power:
Note: On the 1251RP, the maximum output power is limited to 1000VA when the input
voltage is below 120VAC.
2
85V to 264V maximum.
100V to 240V nominal.
15 A RMS max.
47-63 Hertz.
80% (typical) depending on line and load.
0.95 or greater typical.
70 A peak max. at 260V input.
20 ms (with no effect on output).
Input to output = 2200 VAC, input to chassis = 1350 VAC.
0 to 135 V rms or 270 V rms
0.1 volt
1% of range, 50 to 60 Hz.
2% at 400 Hz
1% of FS on low range, 0.5% of FS on high range.
0.5% typical. THD at 50/60 Hz.
800 VA maximum at full scale voltage, either range (Model
801RP).
1250 VA maximum at full scale voltage either range (Model
1251RP).
March 2011
RP Series