Connecting Cpv-Sc Valve Terminal; Pilot Control (Pilot Air) - Festo CPV-SC Series Manual

Valve terminal
Hide thumbs Also See for CPV-SC Series:
Table of Contents

Advertisement

3. Installation
3.3

Connecting CPV-SC valve terminal

3.3.1 Pilot control (pilot air)

3-8
1. If necessary, loosen the locking screw (e.g. with the
loosening tool QSO from Festo) or press the locking ring
of the screw connector.
2. Pull out the tubing.
3. If necessary, replace the screw connector with a blanking
plug 3.
Fig. 3/2: Disconnecting the tubing
Note
– Operate the CPV-SC valve terminal whenever possible
with unlubricated pilot air supply (port 12/14). Other-
wise observe the instructions in the section "Com-
pressed air preparation".
– In the case of CPV-SC valve terminals with internally
branched pilot air supply, the above-mentioned note
also applies to the supply air (connection 1).
Pilot control can be undertaken with internal or external aux-
iliary pilot air, depending on the left-hand end plate. The fol-
lowing end plate pairs are offered for the CPV-SC valve ter-
minal:
3
Festo P.BE-CPVSC-EN en 1206f