Motion System Cleaning & Lubrication - Vision Phoenix 1212 S5 User Manual

Hide thumbs Also See for Phoenix 1212 S5:
Table of Contents

Advertisement

128
Vision Phoenix 1212 S5 User Manual
Then remove the 2 Allen Head Button screws under the back cover on each side of the machine. (Right
side not shown).
Remove the 3 Allen Head Button screws on the inside-front of each side cover. (Right side not shown).
Remove the 9 Phillips Head screws on the bottom of the machine baseplate. Do NOT remove the Allen
Head Cap screws!
The covers can then slide forward and up.
6.5
Motion System Cleaning & Lubrication
Lubricating the X-Axis, Y-Axis and Z-Axis Leadscrews and Linear Rails
A light lubrication of the X, Y and Z-Axis leadscrews should be performed after every month of usage.
Use Teflon-Free Silicone lubricant spray only. Spray a light coating along the entire leadscrew. Note: A
nozzle extender attached to the aerosol spray can help facilitate this procedure and may eliminate the
need to remove the side covers. DO NOT use any lubricant other than Teflon-Free Silicone, as it may
become sticky and cause a buildup that will cause mechanical failure.