Tools Screen
The Tools Screen contains ten buttons and one slider that is associated with the spindle button. The X
button exits this screen and jumps to the screen above. The vise button is used to set the location of the
center of a vise if used on this machine. The inch button toggles the screen units between inch and mm.
The Laser Offset button is used to set the laser pointer offset on the machine at the factory. The Laser
button turns the laser pointer on and off and will be Red when off and blank when on. The Aux 1 button
is used to manually turn the Remote Vacuum Port On or Off and will be Red when off and blank when on.
Aux 2 and Aux 3 buttons are not used on the Express S5 machine. The Fan button turns the cooling
fan On or Off and will be Red when off and blank when on. The Spin button turns the Spindle On or Off
and works in conjunction with the slider next to it which sets the Spindle RPM's. This screen is used to
test or troubleshoot these functions of the machine.
Vise
The vise button is used to set the center location of a self centering vise. Place the vise on the t-slot
table and secure it with the supplied t-nuts. In the tools screen press the vise button and the vise
location screen will appear. Press the X and Y jog buttons on this screen until the laser pointer is in the
center of the vise. Press the green check mark (select) button and the vise offset is now set.