C a l i b r a t i n g t h e S e n s o r ( M a n u a l S e t u p )
When using pre-printed or tinted supply, manually calibrate the sensor.
Select
For
Gap
Calibrate die cut supply:
Follow instructions on screen to place backing paper over the die cut
sensor. Close the cover. Press Select. Then, place label over the
sensor, close the cover and press Select. A message appears with
intensity and threshold readings when successful. If not, recalibrate.
Black Mark
Calibrate black mark supply:
Follow instructions on screen to place a black mark over the black
mark sensor. Close the cover. Press Select. Then, place label or
tag (not black mark) over the sensor, close the cover and press
Select. A message appears with intensity and threshold readings
when successful. If not, recalibrate.
Continuous
Calibrate continuous supply:
Follow instructions on screen to remove supply from the printer.
Close the cover. Press Select. Then, place label or tag in the
printer, close the cover and press Select. A message appears with
intensity and threshold readings when successful. If not, recalibrate.

Sensor Locations

Note the location of the die cut and black mark sensor:
Die Cut S ensor
Classification: Avery Dennison - Public
Black Mark Sensor
Configuring the Media 3-3