C O N F I G U R I N G T H E M E D I A
This chapter explains how to select the supply type and manually calibrate the
sensors.
The media setup options are listed in the table below.
Option
Supply Type
Manual Setup
Threshold Detect
Maximum Length
Advanced
S u p p l y S e t u p I n f o r m a t i o n
When using die cut 4x6 supplies, no calibration is required. The printer calibrates
automatically when supply is loaded and the user presses Feed.
When using pre-printed supply or tinted supply, manually calibrate the sensor.
Choices
Gap/Black Mark/Continuous
Gap/Black Mark/Continuous
Auto/Fixed
1 to 10.0 inches (25mm to 254mm)
On/Off
Classification: Avery Dennison - Public
Default
Gap
NA
Auto
253 mm
OFF

Configuring the Media 3-1