Avery Dennison Corp. Trademarks ZPL II is a registered trademark of ZIH Corp.ZIH Corp. and Avery Dennison are not related in any way, and ZIH Corp. has not licensed or otherwise sponsored the MONARCH® or Avery Dennison printers or the MONARCH LANGUAGE INTERPRETER™.
USING ADVANCED SETUP ......................5-1 Setting the Power-up Mode ....................5-2 Setting the Display Brightness ....................5-2 Setting the Date and Time ..................... 5-2 Setting the Language ......................5-3 Setting MLI Interpreter Options ....................5-3 Classification: Avery Dennison - Public Table of Contents i...
Page 4
USING THE PRINTER MANAGEMENT UTILITY ................A-1 Configuring Ethernet Settings ....................A-1 Configuring WiFi Settings ...................... A-3 Configuring the Printer ......................A-5 Transferring Files ......................... A-6 MENU STRUCTURE ........................B-1 ii Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
G E T T I N G S T A R T E D The Avery Dennison® Monarch® 9419 Printer prints on thermal transfer (ribbon) and thermal direct labels or tags. The printer prints labels continuously (in one strip) or on- demand (one label at a time).
Page 6
Printing a test label or the printer’s configuration, viewing printer information, etc. See Chapter 6, “Using Diagnostics” for more information. Service Contains Service information, which requires a separate password to access. 1-2 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
No symbol, Euro, Chinese, Thai, Korean, Russian, India, Austria, Finland, Sweden, Italy, Spain, France, Germany, Japan, UK, USA Secondary Sign No/Print Decimal Places None/One Digit/Two Digits/Three Digits Two Digits Numeric Format Standard Zero/Slashed Zero Standard Zero Classification: Avery Dennison - Public Configuring the Printer 2-1...
Set the feed mode based on your application and supply type. The default is continuous. Select Continuous Print all tags or labels in a batch (job) in one strip. On-Demand Print one label, once that label is removed, the next label prints. 2-2 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
Selects positive or negative and which position to change. button: or Navigation Increase or decrease the print position to move the print up or down. button: or Classification: Avery Dennison - Public Configuring the Printer 2-3...
Selects positive or negative and which position to change. button: or Navigation Increase or decrease the margin position to move the print left or right. button: or 2-4 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
Print the L. sign. Spain Print the P sign. France Print the F sign. Germany Print the sign. Japan Print the ¥ sign. Print the £ sign. Print the $ sign. Classification: Avery Dennison - Public Configuring the Printer 2-5...
The numeric format sets how the zero character prints; either without a slash, 0 or, with a slash, Ø. The default is Standard Zero. Select Standard Zero Do not print zeroes with a slash. Slash Zero Prints zeroes with a slash (Ø). 2-6 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
When using die cut 4x6 supplies, no calibration is required. The printer calibrates automatically when supply is loaded and the user presses Feed. ♦ When using pre-printed supply or tinted supply, manually calibrate the sensor. Classification: Avery Dennison - Public Configuring the Media 3-1...
Black marks on the back of the supply for sensing. The supply is sensed using the black marks. Tag supply commonly uses black marks. Continuous Continuous supply does not have any index marks for sensing or perforations. 3-2 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
Select. A message appears with intensity and threshold readings when successful. If not, recalibrate. Sensor Locations Note the location of the die cut and black mark sensor: Die Cut S ensor Black Mark Sensor Classification: Avery Dennison - Public Configuring the Media 3-3...
This is helpful when using multiple supply sizes and multiple formats. Note: Operators should calibrate supply whenever changing the supply type or the supply size. 3-4 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
Max. Gap/Mark (maximum gap or black mark length). Do not set the minimum supply length and the maximum gap or black mark length for the sensor’s auto calibration. Classification: Avery Dennison - Public Configuring the Media 3-5...
Communicate at 9600 bits per second. 19200 Communicate at 19200 bits per second. 38400 Communicate at 38400 bits per second. 57600 Communicate at 57600 bits per second. 115200 Communicate at 115200 bits per second. Classification: Avery Dennison - Public Setting Communications 4-1...
A stop bit follows the data and parity bits to signal the end of a character. Select Set the stop bit length to one. Set the stop bit length to two. 4-2 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
A device could have a different IP address every time it connects to the network. 3. Select Yes to save the DHCP setting. The printer reboots and establishes a connection. Or, press No to exit without saving. Classification: Avery Dennison - Public Setting Communications 4-3...
Press Select when finished entering the IP Address, Subnet Mask, and Default Gateway. Press Yes to save the settings. The printer reboots and establishes a connection. Or, press No to exit without saving. 4-4 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
Note: The clock operates on 24-hour time. For example, setting the hours to 16 indicates 4:00 PM. Navigation Increase or decrease the date and time as needed. button: or 5-2 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
S e t t i n g M L I I n t e r p r e t e r O p t i o n s Avery Dennison’s MONARCH LANGUAGE INTERPRETER™ (MLI™) and the Avery Dennison 9419 printer are set up for use with ZIH Corp.’s ZPL II®. If you have any questions about using the 9419 printer with these data streams, please contact your Avery Dennison representative.
Page 26
Disable Reprint last label by pressing “up” button Format Convert Sets bitmap scaling factor None in dpi; first number is the original dpi; second number is desired dpi 5-4 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
From the Main Menu select Diagnostic, then Test Label. Three test labels print: Printer Information MPCL Label Contains the printer’s MPCL packet Contains generic information, including configuration. Refer to the Packet speed, contrast, and inch counts. Reference Manual for more information. Classification: Avery Dennison - Public Using Diagnostics 6-1...
U s i n g t h e S e r v i c e M e n u The Service Diagnostics menu can only be accessed by a Service Representative; it requires a separate password. Classification: Avery Dennison - Public Using Diagnostics 6-3...
Click Discover Device to show printer(s) on the network via Ethernet. Note: The printer’s status appears with an ! (exclamation point) if the printer needs attention – paper jam, out of supplies, open printhead, etc. Classification: Avery Dennison - Public Using the Printer Management Utility A-1...
Page 32
Click Ethernet then press Feed on the printer. Select Static or DHCP. For Static, enter the IP, Subnet Mask, and Default Gateway. Press Set IP when finished. The printer reboots and establishes a connection. A-2 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
Enter your network specific information for SSID, Encryption, etc. Press Set when finished. The printer reboots and establishes a wireless connection. Close the Printer Configuration window. The printer reboots and establishes a wireless connection. Classification: Avery Dennison - Public Using the Printer Management Utility A-3...
C o n f i g u r i n g t h e P r i n t e r From the main Printer Management Utility screen, click Printer Configuration. Make any changes required and click Set. A-4 Online Mode System Administrator’s Guide Classification: Avery Dennison - Public...
Select the File Type to download: BMP, PCX, TrueType font, Bitmap font, Firmware file, etc. Click Browse to navigate to the file. Click Open. Click Download to send the file to the printer. Classification: Avery Dennison - Public Using the Printer Management Utility A-5...
M E N U S T R U C T U R E Use the navigation button then press Select when you see the option you need. Classification: Avery Dennison - Public Menu Structure B-1...