Setting the Parity

Parity checks the validity of data entering the printer. The parity bit immediately follows
the last data bit for a character. The parity bit is adjusted according to the parity so the
data bits in the character, with the parity bit, form an odd or even number when summed.
Select
To
None
Set the parity to none (no parity check).
Odd
Set the parity to odd.
Even
Set the parity to even.

Setting the Data Bits

Data bits specifies how many bits the printer uses to define a character.
Select
To
7
Set the word length to seven.
8
Set the word length to eight.

Setting the Stop Bits

A stop bit follows the data and parity bits to signal the end of a character.
Select
To
1
Set the stop bit length to one.
2
Set the stop bit length to two.