inverters
Goodrive200A
Function
Name
code
The waiting
time of
P01.22
restart after
power off
Start delay
P01.23
time
Delay time of
P01.24
the stop
speed
0Hz output
P01.25
selection
P02 Group Motor 1
Rated power
P02.01
of AM 1
Rated
P02.02
frequency of
AM 1
Rated speed
P02.03
of AM 1
Rated
P02.04
voltage of
AM 1
Detailed instruction of parameters
0: Disable
1: Enable, if the starting need is met, the inverter
will run automatically after waiting for the time
defined by P01.22.
The function determines the waiting time before
the automatic running of the inverter when
powering off and then powering on.
Setting range: 0.0~3600.0s
(valid when P01.21=1)
The function determines the brake release after
the running command is reference, and the
inverter is in a stand-by state and wait for the
delay time set by P01.23
Setting range: 0.0~60.0s
Setting range: 0.0~100.0 s
0: Output without voltage
1: Output with voltage
2: Output at the DC braking current
0.1~3000.0kW
0.01Hz~P00.03(the Max. frequency)
1~36000rpm
0~1200V
40
Function parameters
Default
Modify
value
○
1.0s
○
0.0s
●
0.0s
●
0
Depend
◎
on
model
50.00
◎
Hz
Depend
◎
on
model
Depend
◎
on
model
Need help?
Do you have a question about the Goodrive 200A and is the answer not in the manual?
Questions and answers