NEC MultiSync UN462A User Manual page 119

Large format display
Hide thumbs Also See for MultiSync UN462A:
Table of Contents

Advertisement

MULTI-DSP MENU
ID CONTROL
AUTO ID/IP SETTING
SETTING ITEM
MONITOR ID
IP ADDRESS
ID and IP
BASE NUMBER
BASE ADDRESS
ID/IP SETTING START When [YES] is set, all settings in the [AUTO ID/IP SETTING] are activated.
DETECTED
MONITORS
AUTO ID/IP RESET
RESET ITEM
ID/IP RESET START
DETECTED MONITORS
COMMAND TRANSFER
RESET
Sets the monitor ID number from 1-100 and group ID from A-J. [DETECTED MONITORS] shows the number
of all monitors that are included in the daisy chain of connected LAN cables.
[MONITOR ID] is used for the conditions:
Multiple monitors are connected with LAN.
When remote control is used in ID mode.

NOTE:
Do not turn off the monitors' main power switch or put it into standby while [AUTO ID/IP SETTING] or
[AUTO ID/IP RESET] is activating.
When [SET] is selected, [AUTO ID/IP SETTING] window is shown.
Do not connect network devices between the monitors connected with LAN.
Select an item from [MONITOR ID], [IP ADDRESS] and [ID and IP].
When [YES] is selected the monitor ID numbers are set automatically for all monitors.
Set the first octet to the third octet at [BASE ADDRESS].
The fourth octet is automatically set from "1" and counting up till the number of monitors connected with LAN.
[BASE ADDRESS] is shown when [IP ADDRESS] or [ID and IP] is selected at [SETTING ITEM].
Set [MONITOR ID] and [IP ADDRESS].
Set base number within 100 for the master monitor.
The other monitors that follow in the LAN chain will be given an individual monitor ID automatically. The
monitor ID given to each monitor counts up based on the base number of the master monitor. The monitor ID
range is 1 to 100. Please choose a starting number that is low enough to include all connected monitors.
When [YES] is set, the monitor [IP ADDRESS] is set automatically for all monitors.
This item is shown after [SETTING ITEM] is selected and [ID/IP ADDRESS START] is set to [YES].
If the detected number of monitors and the actual number of MONITOR IDs assigned are different, select
[RETRY] to recount the monitors.
If the shown number is correct, set [CONTINUE].
When [RESET] is selected, [AUTO ID/IP RESET] window is shown.
Select a setting from [MONITOR ID], [IP ADDRESS], and [ID and IP].
When the number of monitors connected with LAN is changed, please select the same item that you selected
at [SETTING ITEM] in the [AUTO ID/IP SETTING] and then run the [AUTO ID/IP RESET].
When [YES] is set, the setting of selected item at [RESET ITEM] returns to default setting.
When the setting returns to default setting, [FINISH!!] is displayed.
NOTE: After [ID/IP RESET START] is activated, the individual settings for [MONITOR ID] and "[IP ADDRESS]
will be reset even though the monitor's are connected with [LAN].
Displays the number of detected monitors.
When [ON] is set, a command is sent to all monitors connected with LAN cables.
Resets all settings within the MULTI DISPLAY menu back to factory setting.
English−115

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multisync un462vaMultisync un552sMultisync un552vs