Setting items

Set refresh target devices of the CPU module.
Select "Use autorefresh" to enable the settings.
Item
Use autorefresh
User CPU Device
Assign devices per buffer
Buffer
Start Address
End Address
[Show I/O Mapping] button
*1 Adding and setting the IO device module in the network configuration setting on GX Configurator-PN display the items.
*2 Note that the setting range does not exceed each device range of the CPU module.
For the device range of the CPU module, refer to the following.
 MELSEC iQ-R CPU Module User's Manual (Application)
Description
Select to enable or disable the refresh settings.
• Not selected: The refresh settings are disabled.
• Selected: The refresh settings are enabled.
Set the start addresses of the transfer source device and transfer destination
device of the CPU module.
With the devices set as the start devices, the range of each buffer memory
area is automatically assigned.
The set devices will be disabled if "Assign devices per buffer" is selected.
Select a method of assigning refresh settings.
• Not selected: Batch assignment
Assigns devices to each buffer memory areas in a batch.
• Selected: Individual assignment
Individually assigns devices to each buffer memory area.
Displays the buffer memory areas of the transfer source device and transfer
destination device of the RJ71PN92.
■Output devices (iQ-R CPU -> PN Controller) tab
• PROFINET Management: PROFINET management output area
*1
• Cyclic Output: Output data area
■Input devices (iQ-R CPU <- PN Controller) tab
• PROFINET Management: PROFINET management input area
*1
• Cyclic Input: Input data area
Set the start addresses of the transfer source device and transfer destination
device of the CPU module.
The set values will be disabled if "Assign devices per buffer" is not selected.
Displays the last addresses of the transfer source device and transfer
destination device of the CPU module.
Displays the list of devices assigned to global labels related to the RJ71PN92
in the HTML format.
Setting range
• Not selected
• Selected
(Default: Selected)
Set this item so that "Start Address"
and "End Address" will be within the
*2
following device range.
• D0 to D10117631
• W0 to W9A61FF
• R0 to R32767
• ZR0 to ZR10027007
(Default: D0)
• Not selected
• Selected
(Default: Not selected)
Set this item so that "Start Address"
and "End Address" will be within the
*2
following device range.
• D0 to D10117631
• W0 to W9A61FF
• R0 to R32767
• ZR0 to ZR10027007
(Default: Refer to the following.)
■Output devices (iQ-R CPU -> PN
Controller) tab
• PROFINET Management: D0
■Input devices (iQ-R CPU <- PN
Controller) tab
• PROFINET Management: D58