Mitsubishi Electric MELSEC iQ-R Series User Manual page 49

Profinet io controller module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Buffer memory address (decimal)
Service response area 1
Service response area 2
57024
59274
57025 to 57026
59275 to 59276
57027
59277
57028 to 57029
59278 to 59279
57030 to 57031
59280 to 59281
57032
59282
57033
59283
57034
59284
*1 For the stored value, refer to the manuals of the IO device.
*2 The number of days elapsed from January 1st, 1970 (UTC) is stored in units of seconds for the alarm acquisition date.
*3 The time elapsed from 0:00:00 (UTC) is stored in units of seconds for the alarm acquisition time.
*4 A value obtained by adding Date area and Time area is treated as UNIX time and the alarm acquisition date and time can be calculated
with this value.
Item name
Stored value
Type
Stores an alarm type.
The values are as follows.
• 0001H: Diagnostics
• 0002H: Process
• 0003H: Drawing
• 0004H: Insertion
• 0005H: Status
• 0006H: Update
• 0007H: Redundancy
• 0008H: Controlled by supervisor
• 0009H: Release
• 000AH: Sub module mounted incorrectly
• 000BH: Sub module restored
• 000CH: Diagnostics disappearance
• 000DH: Multicast communication mismatch notification
• 000EH: Port data change notification
• 000FH: Synchronous data change notification
• 0010H: Isochronous mode problem notification
• 0011H: Network device problem notification
• 0012H: Time data change notification
• 0013H: Dynamic Frame Packing problem notification
• 0014H: MRPD (Media Redundancy for Planned
Duplication) problem notification
• 0015H: Redundancy system
• 001EH: Upload and search notification
• 001FH: Module drawing
• 0020H to 007FH: Manufacturer-specific part
• 0080H to 00FFH: Reserved values for profile
API
API number of the IO device
Priority
Alarm priority
• 0006H: High-priority alarm
• 0005H: Low-priority alarm
Module Ident number
Module ID (This ID has been specified by the IO device
manufacturer.)
Submodule Ident number
Submodule ID (This ID has been specified by the IO
device manufacturer.)
SlotNumber
Slot number of the IO device
SubslotNumber
Sub slot number of the IO device
Specifier
Alarm specifier
• b0 to 10: Sequence number (The value increments
before each request. The value range is 0 to 2047.)
• b11: Path diagnostics (0: Not diagnosable, 1:
Diagnosable)
• b12: Special diagnostics (0: Not diagnosable, 1:
Diagnosable)
• b13: Submodule diagnostics (0: Not diagnosable, 1:
Diagnosable)
• b14: System area
• b15: AR diagnostics (0: Not diagnosable, 1:
Diagnosable)
*1
*1
*1
1 FUNCTIONS
1.3 Service Interface Function
1
47