List of Data Points (HMI-DM, HMI-TM and HMI@WEB controllers)
StateHumidifier
Settings
Date and Time
TimeValidity
Temp modes
Comfort - Heating
Comfort - Cooling
Economic - Heating
Economic - Cooling
ExSpvSupplyTmp
Manual mode
Time schedules
CalendarWeek
CalendarExcept
CalendarOff
Control
humidity
DehumSpvRel
DehumSpvAbs
HumMaxSpv
ActualValueHum
ActCascSpvDeh
HumMaxCtlr
HumidityCtrl
DeHumidityCtrl
Dewpoint
DewpointDedZone
Fans
RegulFans-Flow(Press)
FanSupplyOutputSetpointVal
FanExhaustOutputSetpointVal
FanAddOutputSetpointVal
TRN Correct
Back-up supply fan
Back-up exhaust fan
Fan run-out to DEVV
Fan run-out
MinStOnTimeTrans
60
Menu HMI-DM,HMI-TM a HMI@WEB
Menu
SupplyPrsRangeSnsr
ReturnPrsRangeSnsr
SupplyFlowRangeSnsr
ReturnFlowRangeSnsr
SupplyKFactor
ReturnKFactor
NmbrOfSplyFans
NmbrOfRtrnFans
Enable - K Factor
Fan output 1. stage %
Fan output 2. stage %
Fan output 3. stage %
Fan output 4. stage %
Fan output 5. stage %
Fan output 1. stage %
Fan output 2. stage %
Fan output 3. stage %
Fan output 4. stage %
Fan output 5. stage %
Fan output 1. stage %
Fan output 2. stage %
Fan output 3. stage %
Fan output 4. stage %
Fan output 5. stage %
ValueOfCorrection
FanOutputSt1
FanOutpuSt2
FanOutputSt3
FanOutputSt4
FanOutputSt5
StrtUpDlyFlowMain
StrtUpDlyFlowBackUp
SupplyFanBackUp
StrtUpDlyFlowMain
StrtUpDlyFlowBackUp
ExhaustFanBackUp
Enable
TeplotaVenkovníMin
TeplotaVenkovníMax
Fan run-out
Meaning
Humidifier state
Settings
System time validity
Temperature modes
Comfortable heating
Comfortable cooling
Economy heating
Economy cooling
Extra required inlet air temperature
Manual mode
Time modes
Weekly time schedule
Exception time schedule
Switch-off time schedule
Humidity control
Dehumidification required relative value
Dehumidification required absolute value
Maximum humidity required value
Current humidity value
Calculated current dehumidification required value in cascade control
Maximum humidity
Humidification output
Dehumidification output
Dew point current value
Dew point deviation
Fans
RegulFans-Flow(Press)
SupplyPrsRangeSnsr
ReturnPrsRangeSnsr
SupplyFlowRangeSnsr
ReturnFlowRangeSnsr
SupplyKFactor
ReturnKFactor
NmbrOfSplyFans
NmbrOfRtrnFans
Enable - K Factor
Inlet fan output
Output settings St1
Output settings St2
Output settings St3
Output settings St4
Output settings St5
Outlet fan output
Output settings St1
Output settings St2
Output settings St3
Output settings St4
Output settings St5
Additional fan output
Output settings St1
Output settings St2
Output settings St3
Output settings St4
Output settings St5
Outlet fan speed TRN correction
For all stages
TRN correction for stage 1
TRN correction for stage 2
TRN correction for stage 3
TRN correction for stage 4
TRN correction for stage 5
Single-speed inlet fan backup
Failure flow evaluation time-out after main fan start-up
Failure flow evaluation time-out after backup fan start-up
Active main fan backup
Single-speed outlet fan backup
Failure flow evaluation time-out after main fan start-up
Failure flow evaluation time-out after backup fan start-up
Active main fan backup
Fan run-out according to DEV
Enable run-out
Blocking by the MIN outdoor temperature
Blocking by the MAX outdoor temperature
Fan run-out
Fan run-out
Time transition to 2St speed – two-speed fans
Factory settings
Value
Min
Max
Units
%
Date
and
time
22.6 0
99
°C
24.6 0
99
°C
20.6
0
99
°C
28
0
99
°C
20
0
99
°C
60 0
100
%r.H.
12
0
100
g/kg
80
0
100 %r.H.
%
%
°C
1
-64
64
°C
180
0
9999
s
180
0
9999
s
180
0
9999
s
180
0
9999
s
-15
-64
64
°C
5
-64
64
°C
5
1
60
min
180
0
9999
s
15
0
999
s