List of Data Points (HMI-SG controller)
Parameter
Notation
Reading
code
level
code
level
142
A
Inlet fan output St1 setting (a factor of 10)
143
A
Inlet fan output St2 setting
144
A
Inlet fan output St2 setting (a factor of 10)
145
A
Inlet fan output St3 setting
146
A
Inlet fan output St3 setting (a factor of 10)
147
A
Inlet fan output St4 setting
148
A
Inlet fan output St4 setting (a factor of 10)
149
A
Inlet fan output St5 setting
150
A
Inlet fan output St5 setting (a factor of 10)
151
A
Outlet fan output St1 setting
152
A
Outlet fan output St1 setting (a factor of 10)
153
A
Outlet fan output St2 setting
154
A
Outlet fan output St2 setting (a factor of 10)
155
A
Outlet fan output St3 setting
156
A
Outlet fan output St3 setting (a factor of 10)
157
A
Outlet fan output St4 setting
158
A
Outlet fan output St4 setting (a factor of 10)
159
A
Outlet fan output St5 setting
160
A
Outlet fan output St5 setting (a factor of 10)
161
A
162 U
3rd fan output St1 setting
163
A
164 U
3rd fan output St2 setting
165
A
166 U
3rd fan output St3 setting
167
A
168 U
3rd fan output St4 setting
169
A
170 U
3rd fan output St5 setting
171
A
172 U
Fan run-out after unit stop shut-down
570
A
Enabling the fan run-out according to DEV
571
A
Unit run-out – blocking by the minimum outside temperature
572
A
Unit run-out – blocking by the maximum outside temperature
573
A
Unit run-out – time
Inlet backup – single-speed motors
173
A
174 U
Failure flow evaluation time-out after main fan start-up
175
A
176 U
Failure flow evaluation time-out after backup fan start-up
181 U
Information – backup activation
Outlet backup - single-speed motors
177
A
178 U
Failure flow evaluation time-out after main fan start-up
179
A
180 U
Failure flow evaluation time-out after backup fan start-up
182 U
Information - backup activation
TRN correction
183
A
183 A
Common for all operating stages St
184
A
184 A
For operating stage St1
Control units VCS
Menu HMI-SG
Meaning
0
No
1
Yes
0 non-activated
1 activated
0 non-activated
1 activated
0
- 4 stages
1
- 3 stages
2
- 2 stages
3
- 1 stage
4 0
5
+ 1 stage
6
+ 2 stages
7
+ 3 stages
8
+ 4 stages
0
- 4 stage
1
- 3 stage
2
- 2 stage
3
- 1 stage
4 0
Factory Settings
Value
Min
Max
% (m
/h, Pa)
3
25
% (m
3
/h, Pa)
% (m
3
/h, Pa)
50
% (m
3
/h, Pa)
% (m
3
/h, Pa)
75
% (m
/h, Pa)
3
% (m
/h, Pa)
3
100
% (m
/h, Pa)
3
% (m
3
/h, Pa)
0.1
% (m
3
/h, Pa)
% (m
3
/h, Pa)
25
% (m
3
/h, Pa)
% (m
/h, Pa)
3
50
% (m
/h, Pa)
3
% (m
/h, Pa)
3
75
% (m
3
/h, Pa)
% (m
3
/h, Pa)
100
% (m
3
/h, Pa)
% (m
3
/h, Pa)
0.1
0.1
100
%
25
0.1
100
%
50
0.1
100
%
75
0.1
100
%
100
0.1
100
%
180
0
9999
s
1
-15
-64
64
°C
5
-64
64
°C
5
1
60
Min
180
0
9999
s
180
0
9999
s
180
0
9999
s
180
0
9999
s
0
0
31