Optical Fiber Cables (H-Pcf Cables) - Omron SYSMAC 3G8F7-CLK13-E Operation Manual

Controller link support boards for pci bus
Table of Contents

Advertisement

Connecting H-PCF Cable Optical Ring System Cables
2-2-2

Optical Fiber Cables (H-PCF Cables)

Optical Ring System in
Token Bus Mode
Note
Optical Fiber Cable Accessories
Use the following accessories to assemble and test Optical Fiber Cables.
Name
Optical Fiber Assem-
CAK-0057
bly Tool
Optical Power Tester
S3200-CAT2700
Master Fiber Set
S3200-CAT2001H
An S3200-COCF2071/2571 optical connector can be assembled by adding
the JRFK-57PLUS (Sumitomo Electric Industries) to the S3200-CAK1062.
This manual does not provide details on Optical Fiber Cable preparation. For
details, refer to the instructions provided with the S3200-CAK1062 Assembly
Tool.
No Longer Manufactured
Name
Optical Fiber Assem-
S3200-CAK1062
bly Tool
All of the nodes in the Optical Controller Link Network are connected in a line
(daisy-chain configuration) with H-PCF Optical Fiber Cables.
Begin connection with the rightmost connector (SL1) of the highest node in
the network and connect to the leftmost connector (SL2) in the next lower
node, as shown in the following diagram.
The nodes can be connected in any order, but connect the nodes in the order
of node addresses (i.e., node 1, node 2... node 62) as much as possible to
reduce the effect on the communications time if a wire breaks.
Always cover the unused connectors on the highest and lowest nodes in the
network with the enclosed Optical Connector Covers.
Optical Connector Cover
(Included)
← Higher
Refer to 2-1-1 Devices Required for Connection Devices for details on avail-
able Optical Fiber Cables. Refer to 2-2-3 Installing Connectors for details on
connecting the Optical Fiber Cables to the Controller Link Board.
1. Always use the specified Optical Fiber Cables.
2. The maximum distance between nodes depends on the method used to
attach the connector to the cable.
3. In a system using Optical System Units (model numbers ending CLK11) in
Token Bus Mode (daisy chain connections), the maximum number of
nodes is 32 (i.e., node addresses 1 to 32).
Model
Crimp-cut tool for the S3200-
COCF2071/2571 Connectors
With S3200-CAT2702 Head Unit and
adapter for the S3200-COCF2071/
2571 Connectors
One meter cable for use with the
S3200-CAT2702 Head Unit
Model
Crimp-cut tool for the S3200-
COCF2011/2511 Connectors
Lower →
Section 2-2
Specifications
Specifications
Optical Connector Cover
(Included)
37