Error Log
Error
Contents
code
0211
Duplicate node address error
Hex
(connected to SYSMAC LINK by
mistake)
0214
Node address setting error
Hex
0216
Backup power supply error
Hex
021A
Set table logic error
Hex
021B
Hardware error
Hex
021C
Data link error stopped
Hex
021E
Network line disconnection
Hex
0220
Additional information 1 for num-
Hex
ber of participating nodes
decreased (0206 Hex)
0221
Additional information 2 for num-
Hex
ber of participating nodes
decreased (0206 Hex)
0222
Additional information 3 for num-
Hex
ber of participating nodes
decreased (0206 Hex)
0223
Additional information 4 for num-
Hex
ber of participating nodes
decreased (0206 Hex)
0300
Packet discarded
Hex
0601
Unit error
Hex
Note
152
Detail code
1st byte
2nd byte
00 Hex
Local node
address
Not set
00 Hex
Error type
01 Hex: OFF
to ON
02 Hex: OFF
to ON
00 Hex
01 Hex: Net-
work param-
eters
02 Hex:
Data link
tables
03 Hex:
Routing
tables
00 Hex:
Error status
SL1 error
(See note 4.)
01 Hex:
SL2 error
Not set
Ring status (See note 5.)
Bits 00 to 15 correspond to
disconnected nodes 1 to 16
Bits 00 to 15 correspond to
disconnected nodes 17 to
32
Bits 00 to 15 correspond to
disconnected nodes 33 to
48
Bits 00 to 15 correspond to
disconnected nodes 49 to
62
Not set
Not set
1. Errors indicated by error codes 0101 to 0116 are recorded only when the
frame was discarded because transmission was impossible.
2. Error codes 021E to 0223 Hex are recorded only for Optical Ring Net-
works.
3. Recorded in EEPROM for the 3G8F7-CLK13-E, 3G8F7-CLK23-E, and
3G8F7-CLK53-E.
Correction
Reset so that each node address is
used only once within the same Net-
work.
Correct the node address setting.
Check the backup power supply and
the power supply cables.
Reset the appropriate data.
Replace the Controller Link Support
Board.
Stop the user application, reset the
computer, and retry.
Refer to information in previous sec-
tions of this manual.
Check the network parameters, the
disconnected node, and the cables.
Conduct an echoback test and find
the cause of the error.
Check the operating environment.
Section 9-3
Recorded
in
EEPROM
No (See
note 3.)
Yes
Yes
Yes
No (See
note 3.)
Yes
Yes
No (See
note 3.)
No (See
note 3.)
No (See
note 3.)
No (See
note 3.)
Yes
Yes