Setting Of Remote Device Station - Mitsubishi FX3U User Manual

Melsec-f, cc-link v2
Hide thumbs Also See for FX3U:
Table of Contents

Advertisement

FX
-16CCL-M User's Manual
3U

13.2.3 Setting of remote device station

The figure below shows the setting of the switches in the remote device station.
• FX
-32CCL
2N
• AJ65VBTCU-68DAVN
13 Example of Communication between Master Station
Station number setting switch
0 (
10)
1 (
1)
Number of occupied stations
2 (3 st.)
Transmission speed setting switch
2 (2.5 Mbps)
Station number setting switch,
Transmission speed setting switch
40
OFF
20
OFF
10
OFF
Station
8
OFF
number 4
4
ON
2
OFF
1
OFF
4
OFF
2.5 Mbps
2
OFF
1
OFF
Mode select switch
3 (Ver.2 Mode Normal mode)
13.2 When Remote Net Ver. 2 Mode is Used
11
12
13
14
15
16
A
B
C
155