*1.
The other station data link status takes up to 6 seconds to turn on after a slave station connected to
the master station becomes faulty. The time to turn ON differs according to the system configuration,
faulty status or other conditions.
Name
Indicates the error invalid station specification status by
parameter.
Error
invalid
station
OFF: Not specified
specification status
ON : Specified
(The error code is stored in SW0078.)
Indicates the temporary error invalid station specification
Temporary error invalid
status.
station
specification
OFF: Not specified
status
ON : Specified
(The error code is stored in SW007C.)
Detects change in the setting switches in the master station
Switch change status in
during data link.
master station
OFF: No change
ON : Change
Slave station refresh/
Indicates the parameter-set slave station refresh/compulsory
compulsory
clear
clear setting status in case of programmable controller CPU.
setting status in case of
STOP.
programmable
OFF: Refresh
controller CPU STOP
ON : Clears compulsorily
Indicates the data link status with remote stations and
intelligent device stations.
Data link status in other
OFF: All stations are normal
*1
stations
ON : Some stations are faulty
(The error code is stored in SW0080.)
Indicates the watchdog timer error occurrence status in other
stations.
Watchdog timer error
OFF: No error
status in other stations
ON : Error
(The error code is stored in SW0084.)
Indicates the fuse blowout occurrence status in other
stations.
Fuse blowout status in
OFF: No error
other stations
ON : Error
(The error code is stored in SW0088.)
Detects change in the setting switches in other stations
during data link.
Switch change status in
OFF: No change
other stations
ON : Change
(The error code is stored in SW008C.)
Indicates whether a transient transmission error has occurred
in other stations
Other stations transient
OFF: No error
transmission status
ON : Error
(The error code is stored in SW0094.)
Indicates the accept status of Transmission speed test
Transmission
speed
request.
test accept status
OFF: Not accepted
ON : Accepted
Indicates the completion status of the transmission speed
Transmission
speed
test.
test completion status
OFF: Not completed
ON : Test complete
10.12 Link special relay/Link special register (SB/SW)
Description
10 Buffer Memory
1
Applicability
(
: Applicable,
R/W
: Not applicable)
Online
Offline
2
R/O
R/O
3
R/O
4
R/O
R/O
5
R/O
6
R/O
R/O
7
R/O
8
R/O
R/O
9
10
121

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u-16ccl-m

Table of Contents