Creating A Program For Communication - Mitsubishi FX3U User Manual

Melsec-f, cc-link v2
Hide thumbs Also See for FX3U:
Table of Contents

Advertisement

FX
-16CCL-M User's Manual
3U

15.3.7 Creating a program for communication

This Subsection describes a program to control remote I/O stations, remote device stations and intelligent
device stations.
• The relationship among the PLC, the master station buffer memory, remote I/O stations, remote device
stations and intelligent device stations.
- Remote input (RX) and remote output (RY)
PLC
M115 to M100
M131 to M116
M147 to M132
M163 to M148
(System area)
M179 to M164
M195 to M180
M211 to M196
M227 to M212
M243 to M228
M259 to M244
(System area)
M315 to M300
M331 to M316
(System area)
M347 to M332
M363 to M348
M379 to M364
M395 to M380
M411 to M396
M427 to M412
(System area)
228
Master station
Ver. 1 compatible area
BFM No.
FROM
E0H
instruction
For station
No. 1
E1H
FROM
E2H
instruction
For station
No. 2
E3H
Ver. 2 compatible area
BFM No.
4004H
4005H
FROM
4006H
instruction
Station
No. 3
4007H
4008H
4009H
Ver. 1 compatible area
BFM No.
160H
For station
No. 1
161H
TO
162H
instruction
For station
No. 2
163H
Ver. 2 compatible area
BFM No.
4204H
4205H
TO
4206H
instruction
Station
4207H
No. 3
4208H
4209H
15 Example of Communication in Compound System
15.3 When Remote Net Additional Mode is Used
Remote input (RX)
RX F to RX 0
RX 1F to RX 10
RX 2F to RX 20
RX 3F to RX 30
Remote input (RX)
RX 4F to RX 40
RX 5F to RX 50
RX 6F to RX 60
RX 7F to RX 70
RX 8F to RX 80
RX 9F to RX 90
Remote output (RY)
RY F to RY 0
RY 1F to RY 10
RY 2F to RY 20
RY 3F to RY 30
Remote output (RY)
RY 4F to RY 40
RY 5F to RY 50
RY 6F to RY 60
RY 7F to RY 70
RY 8F to RY 80
RY 9F to RY 90
Remote I/O station
(Station No. 1)
AJ65BTB1-16D
X0F to X00
Ver. 1 compatible
Remote device station
(Station No. 2) FX
-32CCL
2N
Remote input (RX)
RX F to RX 0
RX 1F to RX 10
(System area)
Remote output (RY)
RY F to RY 0
RY 1F to RY 10
(System area)
Ver. 2 compatible
Intelligent device station
(Station No. 3) FX
-64CCL
3U
Remote input (RX)
RX F to RX 0
RX 1F to RX 10
RX 2F to RX 20
RX 3F to RX 30
RX 4F to RX 40
RX 5F to RX 50
(System area))
Remote output (RY)
RY F to RY 0
RY 1F to RY 10
RY 2F to RY 20
RY 3F to RY 30
RY 4F to RY 40
RY 5F to RY 50
(System area)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u-16ccl-m

Table of Contents