Appendix B: Setting Sheet; Appendix B-1 Parameter Setting Sheet - Mitsubishi FX3U User Manual

Melsec-f, cc-link v2
Hide thumbs Also See for FX3U:
Table of Contents

Advertisement

FX
-16CCL-M User's Manual
3U

Appendix B: Setting Sheet

Appendix B-1 Parameter setting sheet

Item
Mode
Number of
connected units
Number of
retries
Number of
automatic return
units
Operation
specification
when CPU is
down
Data link
disorder station
setting
Case of CPU
STOP setting
Reserved
station
specification
Error invalid
station
specification
Station
information
246
Setting range
0: Remote net ver. 1 mode
1: Remote net additional mode
2: Remote net ver. 2 mode
PLC
For FX
/FX
3U
3UC
1 to 16 (units)
For FX
PLC
3G
1 to 12 (units)
1 to 7 (times)
1 to 10 (units)
0: Stop
1: Continue
0: Hold
1: Clear
0: Refresh
1: Clears compulsorily
Set to ON the bits corresponding to the station numbers to
be set as reserved.
Set to ON the bits corresponding to the station numbers to
be set as error invalid stations.
b15 to b12 (Station type)
0H: Ver. 1 compatible remote I/O station
1H: Ver. 1 compatible remote device station
2H: Ver. 1 compatible intelligent device station
5H: Ver. 2 compatible single remote device station
6H: Ver. 2 compatible single intelligent device station
8H: Ver. 2 compatible double remote device station
9H: Ver. 2 compatible double intelligent device station
BH: Ver. 2 compatible quadruple remote device station
CH: Ver. 2 compatible quadruple intelligent device station
EH: Ver. 2 compatible octuple remote device station
FH: Ver. 2 compatible octuple intelligent device station
b11 to b8 (Number of occupied stations)
1H: Occupies 1 station
2H: Occupies 2 stations
3H: Occupies 3 stations
4H: Occupies 4 stations
b7 to b0 (Station No.)
01H to 10H (1 to 16)
Appendix B: Setting Sheet
Appendix B-1 Parameter setting sheet
BFM No.
Default
Hex.
Dec.
#0H
#0
K0
#1H
#1
K8
#2H
#2
K3
#3H
#3
K1
#6H
#6
K0
#0CH
#12
K1
#0DH
#13
K0
#10H
#16
K0
#14H
#20
K0
#20H
#32
0101H
#21H
#33
0102H
#22H
#34
0103H
#23H
#35
0104H
#24H
#36
0105H
#25H
#37
0106H
#26H
#38
0107H
#27H
#39
0108H
#28H
#40
0000H
#29H
#41
0000H
#2AH
#42
0000H
#2BH
#43
0000H
#2CH
#44
0000H
#2DH
#45
0000H
#2EH
#46
0000H
#2FH
#47
0000H
Setting
Remarks
value
-
-
-
-
-
-
-
Station
Nos. 1 to 16
Station
Nos. 1 to 16
1st unit
2nd unit
3rd unit
4th unit
5th unit
6th unit
7th unit
8th unit
9th unit
10th unit
11th unit
12th unit
13th unit
14th unit
15th unit
16th unit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u-16ccl-m

Table of Contents