Introduction Of Functions; Functions List - Mitsubishi FX3U User Manual

Melsec-f, cc-link v2
Hide thumbs Also See for FX3U:
Table of Contents

Advertisement

FX
-16CCL-M User's Manual
3U
6.

Introduction of Functions

6.1

Functions List

1. Basic Functions
Function
Communication
between
station and remote I/O stations
Communication
between
station and remote device stations
Communication
between
station
and
intelligent
stations
Communication
in
system
2. RAS Functions
Function
Slave station cutoff function
Automatic return function
Data link status setting against error
in master station PLC CPU
Setting of input data status from
data link faulty station
Slave station refresh/compulsory
clear
setting
in
programmable
controller
STOP
Consistency control function
3. Handy functions
Function
Reserved station function
Error invalid station function
Temporary
error
specification function
Data link stop/restart
Station
number
overlap
function
Increasing the number of cyclic
points
master
Transfers ON/OFF information with remote I/O stations.
master
Transfers ON/OFF information and the numeric data with remote device stations.
master
device
Transfers ON/OFF information and the numeric data with intelligent device stations.
compound
Transfers data with remote I/O stations, remote device stations and intelligent device
stations.
Cuts off only slave stations in which data link is disabled by power OFF, etc., and
continues the data link using only normal slave stations.
Allows a slave station which was disconnected from the data link by power OFF, etc.
to automatically join the data link again when it recovers to normal status.
Sets the data link status (continue or stop) for a case in which an operation stop error
occurs in the master station PLC.
Sets the status (clear or keep) of the input (receive) data from a station in which data
link is disabled due to power OFF, etc.
case
of
Sets whether output (send) data to the slave stations will be refreshed or compulsorily
CPU
cleared when the programmable controller CPU enters STOP mode.
Consistency control functions assure data consistency for 1 word (16 bits) or more
when read or written by the FROM/TO instructions, or data consistency for 2 words
(32 bits) or more when read or written by the DFROM/DTO instructions.
Sets slave stations to be connected in the future as reserved ones so that such
stations are not handled as data link faulty stations.
Sets slave stations as "error invalid" so that such stations are not handled as data link
faulty stations.
invalid
station
Prevents units specified from being treated as data link faulty stations temporarily
during online operation.
Stops or restarts the data link that is being executed.
check
Checks for the overlapping of number of occupied stations.
Allows the number of cyclic points per module to be increased from 128 points for RX/
RY and 16 points for RWr/RWw in the ver. 1 mode to up to 224 points for RX/RY and
32 points for RWr/RWw in the ver. 2 mode.
6 Introduction of Functions
Outline
Outline
Outline
6.1 Functions List
1
2
Reference
3
Subsection
6.2.1
Subsection
6.2.2
Subsection
6.2.3
4
Subsection
6.2.4
Reference
Subsection
5
6.3.1
Subsection
6.3.2
Subsection
6.3.3
Subsection
6.3.4
6
Subsection
6.3.5
Subsection
6.3.6
7
Reference
Subsection
6.4.1
Subsection
6.4.2
8
Subsection
6.4.3
Subsection
6.4.4
Subsection
6.4.5
9
Subsection
6.4.6
10
41