Generic Names And Abbreviations Used In The Manual - Mitsubishi FX3U User Manual

Melsec-f, cc-link v2
Hide thumbs Also See for FX3U:
Table of Contents

Advertisement

FX
-16CCL-M User's Manual
3U

Generic Names and Abbreviations Used in the Manual

Generic name or abbreviation
PLC
FX
series
3G
FX
PLC or main unit
3G
FX
series
3U
FX
PLC or main unit
3U
FX
series
3UC
FX
PLC or main unit
3UC
Expansion board
Special adapter
I/O extension unit/block
Special function unit/block or
Special extension unit
Special function unit
Special function block
FX
-16CCL-M or
3U
master block
Memory cassette
Battery
FX Series terminal block
Cyclic transmission
Transient transmission
Master station
Local station
Remote I/O station
Remote device station
Remote station
Intelligent device station
Standby master station
Slave station
Remote net ver. 1 mode
Remote net ver. 2 mode
14
Generic name for FX
Series PLC
3G
Generic name for FX
Series PLC main unit
3G
Generic name for FX
Series PLC
3U
Generic name for FX
Series PLC main unit
3U
Generic name for FX
Series PLC
3UC
Generic name for FX
Series PLC main unit
3UC
Generic name for expansion board
The number of connectable units, however, depends on the type of main unit.
To check the number of connectable units, refer to the User's Manual - Hardware Edition of the main
unit to be used for your system.
Generic name for high-speed input/output special adapter, communication special adapter, analog
special adapter, and CF card special adapter.
The number of connectable units, however, depends on the type of main unit.
To check the number of connectable units, refer to the User's Manual - Hardware Edition of the main
unit to be used for your system.
Generic name for input/output powered extension unit and input/output extension block
The number of connectable units, however, depends on the type of main unit.
To check the number of connectable units, refer to the User's Manual - Hardware Edition of the main
unit to be used for your system.
Generic name for special function unit and special function block
The number of connectable units, however, depends on the type of main unit.
To check the number of connectable units, refer to the User's Manual - Hardware Edition of the main
unit to be used for your system.
Generic name for special function unit
Generic name for special function block
Abbreviated name for FX
-16CCL-M
3U
Generic name for memory cassette.
The number of connectable units, however, depends on the type of main unit.
To check the number of connectable units, refer to the User's Manual - Hardware Edition of the main
unit to be used for your system.
Abbreviated name for FX
-32BL
3U
Generic name for FX Series terminal block.
The number of connectable units, however, depends on the type of main unit.
To check the number of connectable units, refer to the User's Manual - Hardware Edition of the main
unit to be used for your system.
Transmission method by which data of remote I/O and remote registers are refreshed periodically.
Transmission method by which 1:1 communication can be performed with the target specified and at
any timing.
Station which controls the data link system. One master station is required in one system.
Station having a programmable controller CPU and the ability to communicate with the master and
other local stations.
Remote station that handles bit data only. (Performs input and output with external devices.)
Remote station that handles bit and word data. (Performs input and output with external devices, and
analog data conversion.)
General name for remote I/O station and remote device station.
Controlled by the master station.
Generic term for the stations that can perform transient transmission, such as the FX
Backup station for data link control when the link to the master station is disconnected due to a
programmable controller CPU or power supply problem.
General name for remote I/O station, remote device station, and intelligent device station.
Mode in which compatibility with the conventional unit (FX
Select this mode when the number of cyclic points need not be increased or when the FX
M is used to replace the conventional unit as a maintenance product.
Select this mode when increasing the number of cyclic points and configuring a new system.
Generic Names and Abbreviations Used in the Manual
Description
-16CCL-M) is achieved.
2N
-64CCL.
3U
-16CCL-
2N

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u-16ccl-m

Table of Contents