Pressurized Water System-Helpful Hints
1. Water pressure pump cycles on
and off. Normally this type of action
indicates a water leak in the system.
Check all water system related equip-
ment on the deck and engine com-
partment for leaks. Look for puddled or dripping
water.
2. Using water system the water pressure is weak.
Check the fresh water pressure pump filter for de-
bris. Also, make sure the water tank level is suf-
ficient.
3. Water at sink or transom shower is hammering
and has air bubbles in it. Check for air leaks in the
system along with low water levels in the water
tank.
4. There is no water at any of the water related
equipment including head faucet or transom
shower. Check to make sure the water pressure
pump switch is activated. Also, check for a blown
fuse.
5. The water system has a bad odor. Use the pres-
surized water pressure pump to drain the water
system. Do not permit anyone to drink the water as
it may be contaminated and it is not a potable water
system. Sanitize the water system.