Visonic PowerMaster 360 Installer's Manual page 53

Table of Contents

Advertisement

Option
E-MAIL TEST
1
Depending on shock detector model, one of the following may appear instead: "Zxx:Shk+AX" / " Zxx:Shk+CntG3" /" Zxx:Shk+CntG2".
D-305735 PowerMaster 360 Installer's Guide
Instructions
To test the microwave range, go to step 5. To test a different microwave range, go to step 7.
5. Press
; the following screen will appear: "ACTIVATE MW NOW".
6.
Activate the device; the screen will return to "TEST ONE DEVICE".
You can now repeat the procedure for another dual detector.
7. Press
to select the sensitivity setting.
8. Press
continuously to select between "Minimum" (default), "Medium" or "Maximum"
9a. Press
; the panel will receive an acknowledge from the device that is indicated by a
black box next to the selected setting. Thereafter, the screen momentarily changes to
"ACTIVATE MW NOW" and then returns to the selected setting.
9b. If you press
Important: The procedure mentioned above is for testing purposes only and does not change
the detector settings. The settings must be saved through the MODIFY DEVICES menu.
To test the shock detector:
1. Press
to enter the "TEST ONE DEVICE" sub menu and use
"SHOCK SENSORS".
2. Press
; the following screens will appear: "Zxx:Shk+AX+CntG3"
3. Press
continuously to select a different zone number.
4. Press
; the following screens will appear: "Zxx ACTIVATE NOW"
ACTIV."
"CNTACT NOT ACTIV"
Note: The above screens are the full range of screens that can appear and indicate the
inputs that have not yet been activated. However, since there are various models of the
shock detector, not all of these screens will appear on some models.
5.
At this stage, activate each input of the shock detector in turn.
To test motion detector with integrated camera (Next CAM PG2 or TOWER CAM PG2):
1. Press
to enter the "TEST ONE DEVICE" sub menu and use
"MOTION SENSORS".
2. Press
; the following screens will appear: "Z01:Motion Sens"
3. Press
continuously to select a different zone number.
4. Press
; the following screen will appear: "Zxx ACTIVATE NOW".
5.
Activate the input of the detector; the following screens will appear: "<Zxx IS
ACTIVATE>"
"<OK> SEND IMAGE".
To test emails, proceed as follows:
While in "E-MAIL TEST", press
The following screen will appear: "Please wait..." and at the termination of the test will
change to <Pls chck MailBox>.
Check the private email inbox to view the sent email.
Note:
1. For test success, the event must first reach the server before the server can send the
email to the user's inbox.
2. Since a Burglary alarm is sent, an alarm event must be configured for reporting events
(see sections 4.6.3 "Configuring Events Reporting to Monitoring Stations" and 4.6.4
"Configuring Events Reporting to Private Users").
, the adjustment procedure ends.
"AUXIL. NOT ACTIV".
to initiate the test.
5. PERIODIC TEST
to navigate to
1
<location>.
"SHOCK NOT
to navigate to
<location>.
53