4.2.2 Selecting options

– Selecting an option from a menu
Example: To Select an Option from the "COMMUNICATION" menu:
[1]
Enter the Installer Mode menu and select the "04.COMMUNICATION" option (see section 4.2).
[2]
Select the sub-menu option you need, for example: "3: C.S. REPORTING".
[3]
Select the parameter you wish to configure for example: "11:RCVR 1 ACCOUNT"
[4]
To continue, go to the section of the selected sub-menu option, for example section 4.6.3 for the
"3:C.S.REPORTING" menu, and look for the sub-menu you wish to configure (e.g. "11:RCVR 1 ACCOUNT"). After
configuring the selected parameter the display returns to step 3.
To Change the Configuration of the Selected Option:
When entering the selected option, the display shows the default (or the previously selected) setting marked with .
To change the configuration, scroll
confirm. When done, the display reverts to Step 3.

4.2.3 Exiting the Installer Mode

To exit the Installer Mode, proceed as follows:
Step 1
[1]
Any screen
– Exiting the Installer Mode
To exit "INSTALLER MODE", move up the menu by pressing the
[1]
reads "<OK> TO EXIT" or preferably; press the
screen "<OK> TO EXIT".
When the display reads "<OK> TO EXIT", press
[2]
The system exits the "INSTALLER MODE" menu and returns to the normal disarm state while showing the
[3]
READY display.

4.3 Setting Installer Codes

The PowerMaster 360 system provides two installer permission levels with separate installer codes, as follows:
Master Installer: The "Master Installer" is authorized to access all Installer Mode menu and sub-menu options. The
default code is: 9999 (*).
Installer: The "Installer" is authorized to access most but not all Installer Mode menu and sub-menu options. The
default code is 8888 (*).
Guard Code: Enables an authorized guard to only Arm Away / Disarm the control panel. The default code is 0000 (*).
The following actions can be performed only by using the Master Installer code:
Changing the Master Installer code.
Defining specific communication parameters – see "3:C.S REPORTING" in sections 4.6.2 and 4.6.3.
Resetting the PowerMaster 360 parameters to the default parameters – see "09:FACTORY DEFLT" in section
4.11.
Note: Not every system includes a Master Installer code feature. In such systems, the Installer can access all Installer
Mode menu and sub-menu options the same as a Master Installer.
(*) You are expected to use the default codes only once for gaining initial access, and replace it with a secret
code known only to yourself.
D-305735 PowerMaster 360 Installer's Guide
the "Options" menu and select the setting you wish and press
Step 2
or
<OK> TO EXIT
Step 3
[2]
[3]
READY 12:00
button repeatedly until the display
button once which brings you immediately to the exit
.
4. PROGRAMMING
to
15