4. PROGRAMMING
To change your Master Installer or Installer Codes proceed as follows:
Step 1
Select "01:INSTALL
CODES" Option
INSTALLER MODE
ENTER CODE:
01:INSTALL CODES
– Setting Installer Codes
Enter the Installer Mode menu and select the "01:INSTALL CODES" option (see section 4.2).
[1]
Select the "NEW MASTER CODE", "NEW INST. CODE" or "NEW GUARD CODE". Some panels may have
[2]
only the Installer Code and New Guard Code option.
[3]
Enter the new 4-digit Code at the position of the blinking cursor and then press
Notes:
1.
Code "0000" is not valid for Master Installer or installer.
2.
Inserting "0000" for the Installer will delete the Installer Code.
3. Warning! Always use different codes for the Master Installer, for the Installer and for the Users.
If the Master Installer Code is identical to the Installer code, the panel will not be able to recognize the
Master Installer. In such a case, you must change the Installer code to a different code. This will re-validate
the Master Installer code.
4.3.1

Identical Installer and Master Installer Codes

In a 2-installer code system, the non-master installer may inadvertently change his Installer Code to that of the Master
Installer Code. In this case, the panel will allow the change in order to prevent the non-master installer from realizing
the discovery of the Master Installer's Code. The next time the Master Installer enters the Installer Mode the Master
Installer will be considered as an Installer and not as a Master Installer. In such a case the Master Installer should use
one of the following solutions:
(a) Access the panel using the Remote Programmer PC software application and change the Master Installer Code to
a different code than the one programmed by the Installer.
(b) 1. Change the Installer Code to a temporary code, 2. exit the Installer Mode, 3. enter the Installer Mode again using
the Master Installer code (the Master Installer Code will now be accepted), 4. change the Master Installer code to a
different code, 5. and change the NON-Master Installer Code back again (in other words, undo the change to the
temporary code) so that the NON-Master Installer can still enter the system.

4.4 Zones / Devices

4.4.1 General Guidance & Zones/Devices Menu Options
The ZONES/DEVICES menu enables you to add new devices to the system, to configure them and to delete them, if
required.
To select an option follow the instructions below. Additional details and guidance are provided in section 4.2.
INSTALLER MODE
Option
ADD NEW DEVICES
DELETE DEVICES
MODIFY DEVICES
REPLACE DEVICES
ADD TO SOAK TEST
DEFINE DEFAULTS
16
Step 2
[1]
Select Master Installer,
Installer code or Guard
code
NEW MASTER CODE
or
NEW INST. CODE
or
NEW GUARD CODE
02:ZONES/DEVICES
Use
Use to enroll and configure the device's operation according to your preference
and in case of sensors to also define their zone name (location), zone type and
chime operation.
Use to delete devices from the system and to reset their configuration.
Use to review and/or change the device's configuration.
Use to replace faulty devices with automatic configuration of the new device.
Use to enable the Soak Test for device zones.
Use to customize the defaults of the device's parameters according to your
personal preferences for each new device enrolled in the system.
Step 3
[2]
Enter NEW Master Installer,
Installer code or Guard code
MASTER CODE
INST. CODE
GUARD CODE
MENU you wish
D-305735 PowerMaster 360 Installer's Guide
Step 4
[3]
999
or
888
or
000
.
indicates scroll
to step 2
to step 2
to step 2
and select
Section
4.4.2
4.4.3
4.4.4
4.4.5
4.4.6
4.4.7