4. PROGRAMMING
64:MISS/JAM ALRM
Previously known as
"
"BELL/REP.OPT
65:SMOK FAST MIS

4.5.8 Configuring Miscellaneous Features

The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 4.5.1.
Option
Configuration Instructions
User Permission enables you to determine whether access to the INSTALLER MODE requires
91:USER PERMIT
the user's permission or not. If you select enabled, the installer will be able to access the system
only through the user menu after the user code has been entered (see section 4.2).
Options: disable (default) or enable (default in UK).
Note: To comply with EN requirements, "Enable" must be selected.
Define the period of time for the Soak Test.
93:SOAK PERIOD
Options: Disable (default), 7 days, 14 days or 21 days.
Notes:
1. If set to one of the above pre-defined period of times, to be operational Soak Test mode must
2. If a change is made to the period of time of the Soak Test while the zone is currently being
3. The start of the Soak Test period is defined in the factory from 9 AM (09:00).
30
"EN/UL standards" require that if a supervision (missing) or jamming trouble occurs during
AWAY arming, the siren will sound and the event will be reported as a tamper event.
Define whether the system will behave according to EN standard or as normal (default).
Note: To comply with EN requirements "EN standard" must be selected.
Determine that If the smoke detector does not report at least once within a time window of 200
seconds, a "MISSING" alert is initiated.
Options: Disabled (default) and Enabled.
also be set to "Enable Test" from the "02:ZONES/DEVICES" menu (see Section 4.4.6).
tested, this will restart the Soak Test.
D-305735 PowerMaster 360 Installer's Guide