4.4.36 User Permission

(Fig. 4.4, location 36). Here you determine whether the
access to the INSTALLER MODE requires user permission.
If you select ENABLE, the installer mode will be accessible
only through the user menu after entering the user code.
Options: Enable, Disable.
Note: This menu is not available when partition is enabled.
D-302017

4.4.39 Key Zones Options (Optional)

(Fig. 4.4, location 39). Here you determine whether or not
the system can be armed and disarmed by zones 21-18, 29
or 21-29, provided that for these zones "non-alarm type"
and "z-key enable" was predefined (see par. 4.3).
Key zones can be wireless or wired zones.
When using wireless key zones, only the MCT-100 and
MCT-102 transmitters are used. The left pushbutton on the
MCT-102 transmitter or input 1 of the MCT-100 transmitter
is used for arming in AWAY mode. The right pushbutton
on the MCT-102 transmitter or input 2 of the MCT-100
transmitter is used for disarming.
When using wired key zones, the control panel toggles
between AWAY mode and Disarm.
Note: In "Singapore" versions of the PowerMaxExpress,
an open circuit arms the alarm system in AWAY mode and
a closed circuit changes the state of the alarm system from
AWAY mode to Disarm.
IMPORTANT! Enrolment of the MCT-100 or MCT-102
transmitter must be performed via the left pushbutton on
the MCT-102 transmitter or input 1 of the MCT-100
transmitter.
Caution! Arming the system using a transmitter
assigned to zones 21 and 28, or via wired zone 29
compromises security. This function is, therefore, only
available
in
specific
according to the customer's request.
Options: disable option, z. 21-28 enable, z. 29 enable, or
z. 21-29 enable.
PowerMaxExpress
versions
15